IMAGE+ technical specifications

measurement system: optical/ no laser

  • measurement system: optical/ no laser
  • scanning area: realtime with FOV 62° (=^ 29mm focal length)
  • range: 0.5m to > 15m (2ft to 50ft)
  • accuracy: +-1cm @2m (0.5" @ 7ft)
  • sampling rate: 30fps
  • measurement: orthogonal measurement
  • IMU-2 size: 19 x 5.5 x 4.5cm3
  • IMU-2 weight: 480g (1lbs)
  • temperature: -10°C - +50°C
  • power: 10V - 34V/15W
  • different interfaces:
    • extermal peripheries: Ethernet
    • lens control system: RS232
    • direct motor control: CAN
IMU-2_fronttotale